You could also opt for a pvc flat roofing membrane.
Minimum roof pitch for fiberglass shingles.
The minimum pitch for shingles is 1 6 which is equivalent to 4 inches rise to 24 inches run.
They provide excellent weather resistance great value and now more than ever a tremendous range of beautiful designs and color blends.
Owens corning produces high quality asphalt coating asphalt sealants and adhesives for asphalt shingles.
Metal roof shingles require a minimum roof pitch of 3 12 or greater.
Let us recap on the minimum roof pitch required for each type of roofing material.
Asphalt shingles require a minimum roof pitch of 2 12 or greater.
The 2 12 number is rise over run or two units of vertical for every 12 units horizontal.
Experience the total owens corning roofing system and high quality roofing shingles.
Slopes above 19 12 are not recommended since tiles on very steep roofs can rattle.
So you would need to pick the right option as most regular standing seam metal roofs will require a roof pitch of 2 12 or even 3 12 at a minimum.
Installation on roof slopes below a 2 in 12 pitch is not recommended at all.
To get the minimum pitch for a metal roof the vertical rise per foot is divided by the horizontal slope.
The minimum pitch for a standing seam metal roof is 1 4 or 3 inches rise to 12 inches run.
Clay and concrete tile requires a minimum roof pitch of 2 1 2 12 or greater.
Corrugated metal roofing has the same minimum pitch.
The minimum requirement is 2 12.
2 5 12 to 19 12 pitches clay or cement tiles can be used on a wide range of roof pitches.
We can even help you find a professional to install it.
For pitches of 2 5 12 up to 4 12 the roof requires double underlayment.
That works out to about nine degrees if that works better for you.
Minimum pitch for metal roof.
The minimum roof slope for metal roofs is dependent upon the roof profile.
The asphalt shingle manufactures recommend that you install asphalt shingles on a recommended minimum of 4 in 12 or greater however most manufactures will warrant their shingles down to a 2 in 12 pitch if the recommended installation method is used.
Shingles of all types need to have a slope to function properly.
The pitch is measured in inches of vertical rise per foot of horizontal run and the 5v crimp profile shown above requires a minimum slope of three in twelve or 3 12 3 inches vertically per 12 inches horizontally.
With regards to metal roofing the profile refers to the shape adopted by the metal sheets when they are bent to form the panels.
There are some standing seam metal roofing options available from atas and other manufacturers that can be installed on a roof with pitch of 1 12.