Interior moisture sources such as humidifiers unvented clothes dryers bathrooms and cooking as well as the moisture in concrete after construction.
Moisture in concrete walls.
When you read in a sealer data sheet that the mver needs to be 3 pounds or 5 pounds what that means is the number of pounds of water vapor per 1000 square feet per 24 hours.
It also saturates insulation reducing energy efficiency.
Exterior humid air that enters the basement and condenses on cooler surfaces.
There are just three sources of moisture.
For example if the temperature in the room is around 80 degrees fahrenheit and the rh is 50 then a safe level of moisture in the wall would be about 9 1 mc.
Liquid water from rain or ground water.
Concrete masonry walls are less affected by the problems associated with moisture infiltration and condensate than other building materials i e.
In extreme cases moisture intrusion leads to spalling and could even necessitate wall replacement.
Moisture supports the growth of mold and causes wall coatings to blister and peel.
Water vapor leaves the surface of a concrete slab at a rate that is called the moisture vapor emission rate mver.
The science behind moisture in walls is easy to understand.
Acceptable moisture levels in concrete according to astm standard when testing via astm f2170 the rh level of a concrete slab needs to be at or below 75 unless the flooring system manufacturer provides alternate guidelines.
Condensation proves a pervasive threat to buildings especially walls and concrete foundations.
Some flooring system manufacturers have products that can handle 95 rh or mor 2.
Measuring moisture in walls.
Corrosion rotting mold delamination blistering and volumetric changes.
Concrete is like a sponge absorbing moisture from under the concrete which causes the moisture to come up through the concrete capillaries.
How moisture gets into concrete.
If you have damp patches bubbling paint crumbling plaster or powdery deposits on wall surfaces close to the floor rising damp is probably the culprit.
In commercial buildings the uncontrolled intrusion of moisture into concrete and masonry walls may have costly consequences.
As mentioned above condensation leaks and inadequate drainage are generally the most common causes of moisture issues.
So how can you be sure if the walls in a structure have a safe level of moisture.
Read our tips for concrete moisture testing in the real world to learn more about concrete moisture testing.
Above grade and below grade water can weaken the structure of a building by causing rotting corrosion and many more moisture induced issues.
Controlling moisture in masonry is essential to preserving the integrity of your building projects.